EasyManua.ls Logo

Mahindra XUV700 2021 - Page 99

Mahindra XUV700 2021
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by
the manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present
document, are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of
Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution© 2021 Mahindra & Mahindra Ltd.
99
OK NOT OK
Go to step 3
Check the wiring harness for any open or
short circuit and replace or repair the wiring
harness
STEP 3 CHECK THE BATTERY VOLTAGE IN IGNITION INPUT WIRE
PRE CONDITION
Ignition OFF
Remove the UICU connector C 116
Ignition ON
TEST PROCEDURE
Check the battery voltage at pin number 6 of C 116
ACCEPTANCE CRITERIA
Is the battery voltage is 12V
ACTION TO BE TAKEN
OK NOT OK
Go to step 4
Check the wiring harness for any open or
short circuit and replace or repair the wiring
harness
STEP 4 CHECK THE UICU GROUND WIRE
PRE CONDITION
Ignition OFF
Remove the UICU connector C 116
Remove the ground terminal G 25
TEST PROCEDURE
Check for resistance between pin number 4 of C 116 and G 25 ground point wire end
ACCEPTANCE CRITERIA
Is the resistance value is <1Ω
ACTION TO BE TAKEN
Diagnostic Manual
XUV700 (Diesel)
UICU
MAN-01065
OCT - 2021/Rev 1

Table of Contents