Inductance (Manual-ranging)
AccuracyRange
11.000mH
110.00mH
11.000H
Resolution
1uH
10uH
1mH
±2.0% of rdg ±0.05mH
±5.0% of rdg ± 0.05H
20.00H 10mH
±5.0% of rdg ± 0.2H
Maximum Input: 600V DC or 600V AC RMS
Diode Test
AccuracyTest current
0.3mA typical
Resolution
1 mV
±10% of rdg ± 5 dgts
Open circuit voltage: 1.1V DC typical
Overload protection: 600V DC or AC RMS.
Audible continuity
Audible threshold: Less than 30Ω; Test current: <0.3mA
Overload protection: 600V DC or AC RMS.
OPERATION
1. ALWAYS turn the function switch to the OFF position when the
meter is not in use. This meter has Auto OFF that automatically
shuts the meter OFF if 15 minutes elapse between uses.
2. If “OL” appears in the display during a measurement, the value
exceeds the range you have selected. Change to a higher range.