AUTO RANGING/MANUAL RANGE SELECTION
When the meter is first turned on, it automatically goes into Auto
ranging. This automatically selects the best range for the measurements
being made and is generally the best mode for most measurements. For
measurement situations requiring that a range be manually selected,
perform the following:
1. Press the RANGE key. The “AUTO” display indicator will turn off or
select diode /beeper, AC/DC Clamp
2. Press the RANGE key to step through the available ranges until you
select the range you want.
3. To exit the Manual Ranging mode and return to Auto ranging, press
and hold the RANGE key for 2 seconds.
MAX/MIN
Note: When using the MAX/MIN function in Autoranging mode, the
meter will “lock” into the range that is displayed on the LCD when
MAX/MIN is activated. If a MAX/MIN reading exceeds that range, an
OL” will be displayed. Select the desired range BEFORE entering
MAX/MIN mode.
1. Press the MAX/MIN key to activate the MAX/MIN recording
mode. The display icon "MAX" will appear. The meter will display
and hold the maximum reading and will update only when a new
MAX” occurs.
2. Press the MAX/MIN key again and the display icon "MIN" will
appear. The meter will display and hold the minimum reading and
will update only when a new “MIN” occurs.
3. To exit MAX/MIN mode press and hold the MAX/MIN key for 2
seconds