The exhaust gas velocities are based on the pipe
dimensions in the table below
DN
Nominal diameter
D1
mm
D2
mm
T
mm
Flow area
A
10
-3
m
2
300 323.9 309.7 7.1 75.331
350 355.6 339.6 8.0 90.579
400 406.4 388.8 8.8 118.725
450 457.0 437.0 10.0 149.987
500 508.0 486.0 11.0 185.508
550 559.0 534.0 12.5 223.961
600 610.0 585.0 12.5 268.783
650 660.0 650.0 5.0 331.830