m&h Inprocess Messtechnik GmbH x Am Langholz 11 x D-88289 Waldburg
Fon +49(0)7529 / 9733-0
x Fax +49 (0)7529 / 9733-7 x vertrieb@mh-inprocess.com
Infrared Probe 40.01
-
TX/RX
www.mh
-
in
p
rocess.com
OPERATING INSTRUCTIONS
(Translation of the original operating instructions)
Page
System Components, Technical Data, Dimensions 1
Probe ON / OFF Angle, Transmitting / Receiving 2
Stylus Change, Battery Replacement, Optical Status Display 3
Aligning Stylus to Spindle Centre 4
Infrared Signal Range / Power Off Delay / Battery Life,
Maintenance, Cleaning Jets 5
Shank Mounting, HSK Shanks 6
SK Shanks, Coromant Capto Shanks
Tool Holder VDI 7
Other Shanks, THERMO-LOCK
®
Shanks,
Aligning probe in shank with 90° Adapter 8
Styli 9
Spare Parts, Accessories 10
BA4001-TX/RX-3010-WEST Subject to change without notice
Question and Answer IconNeed help?

Do you have a question about the m&h Inprocess 40.01-TX and is the answer not in the manual?

m&h Inprocess 40.01-TX Specifications

General IconGeneral
Brandm&h Inprocess
Model40.01-TX
CategoryMeasuring Instruments
LanguageEnglish

Summary

System Components, Technical Data, and Dimensions

Technical Specifications

Lists key technical data such as probing directions, overtravel, probing force, speed, power supply, material, and repeatability.

Probe Operational Angles and Signal Transmission

Probe ON/OFF Angle Settings

Explains the angular range for probe activation and deactivation, including an ON/OFF procedure diagram.

Transmitting and Receiving Capabilities

Illustrates the angular coverage for transmitting and receiving signals, detailing range settings for the probe.

Stylus, Battery, and Status Indicators

Battery Replacement Guide

Instructions for replacing the probe's battery, including battery types and attention points for maintenance.

Stylus Alignment to Spindle Centre

Rough Alignment Procedure (<20μ)

Step-by-step guide to achieving initial stylus alignment to the spindle centre within a 20μ tolerance.

Fine Alignment Procedure (<2μ)

Detailed instructions for fine-tuning the stylus alignment to achieve a runout of less than 2μ.

Signal Range, Power Off Delay, and Maintenance

Infrared Signal Range and Power Off Delay Settings

Describes selectable infrared signal ranges and power-off delay settings, impacting battery life.

Shank Mounting and Types

Specialized Shanks and Alignment Adapters

90° Adapter Alignment Procedure

Steps for aligning the probe in a shank using a 90° adapter, involving adjustment and clamping screws.

Spare Parts and Accessories