3. Remove the old battery (3) from the holder, then, disconnect
the battery by squeezing while pulling on the connector (4).
4. Install replacement battery.
Replace PLC Battery
Items required:
1 - PLC Battery (M&R Part No. 1017515)
IMPORTANT: This procedure requires electrical power to be
connected to the press.
IMPORTANT: The new battery must be installed within five
minutes of removal of the old battery. This will ensure the
preservation of program data in the PLC memory.
1. Open the access door on the lower electrical enclosure
mounted to the indexer chassis.
2. Locate the PLC module (1) mounted to the rear upright wall
inside the enclosure. Swing open the access cover on the
PLC module to expose the battery (2).
3. Remove the old battery (3) from the holder, then, disconnect
the battery by squeezing while pulling on the connector (4).