ELECTRICITY
132
547379EN
80 (08/03/2017)
OVERLOAD SIGNAL
- The reference of the overload signal is emitted by the basket card, output Do 18 (wire 335)................
(680.1 ELECTRICAL SCHEMATIC DIAGRAMS, 5 73)
MULTIMETER TEST
Overload sensor SQ5a Measure using the calibrator Multimeter
Weight in the basket Wire N° Menu Description Message To card Display
< 200 kg (441 lbs) 333
1.3.16 Cage Ovl 2
(F4) Safety (F4)
> 200 kg (441 lbs) 333 Open Safety No signal
Overload sensor SQ5b Measure using the calibrator Multimeter
Weight in the basket Wire N° Menu Description Message To card Display
< 200 kg (441 lbs) 332
2.4.9 Cage Ovl 2
(F4) Safety (F4)
> 200 kg (441 lbs) 332 Open Safety No signal
24V
1 s
OPEN
CLOSED
OPEN
CLOSED
5s 5s
1 s
0.6V
U(V)
t(s)
Multimeter
reading
Calibrator
reading