34 Part Number STH038 5/12
Step 11 Use 1/2 of the sanitizer/water solution to
sanitize all food zone surfaces of the ice machine and
bin (or dispenser). Use a spray bottle to liberally apply
the solution. When sanitizing, pay particular attention
to the following areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom and
sides
Bin or dispenser
Do not rinse the sanitized areas.
Step 12 Replace all removed components.
Step 13 Wait 20 minutes.
Step 14 Reapply power to the ice machine and press
the Clean button.
Step 15 Wait until the water trough refills and the
display indicates add solution (approximately 1
minute). Add the proper amount of Manitowoc Ice
Machine Sanitizer to the water trough by pouring
between the water curtain and evaporator.
Step 16 Select auto ice on, press the checkmark and
close and secure the front door. The ice machine will
automatically start ice making after the sanitize cycle
is complete (approximately 24 minutes).
Model Amount of Sanitizer
I0320 90 ml (3 oz)
I0500 90 ml (3 oz)