3 For your safety
eikon e2s Service and Repair Manual UL 41
Item Safety device
Function
Check
6
(no picture,
installed by
customer)
Disconnection device
Installed by the customer close
to the appliance; easily visible
and accessible, 1- or 3-pole
action, minimum contact separa-
tion 3 mm.
Used to disconnect the appliance
from the power supply during
cleaning, repair and servicing
work and in case of danger
Action:
Trip the disconnection device
7
(no picture)
Internal fuses
Prevent faulty components from
drawing too much current and
causing potential fire hazard.
Ensure that the internal fuses are
correctly rated