44 Part Number STH039 8/13
Water Level Check
The float valve is factory-set for the proper water level.
If adjustments are necessary:
1. Verify the ice machine is level.
2. Remove the siphon cap from the standpipe.
3. Place the main ON/OFF/WASH toggle switch to
the ON position, and wait until the float valve
stops adding water.
4. Adjust the water level 6 mm to 10mm below the
standpipe, to the line in the water trough:
A. Loosen the two screws on the float valve
bracket.
B. Raise or lower the float valve assembly as
necessary, then tighten the screws.
5. Move the main ON/OFF/WASH toggle switch to
the OFF position. The water level in the trough will
rise above the standpipe and run down the drain.
6. Replace the siphon cap on the standpipe, and
verify water level and siphon action by repeating
steps 3 through 5.