EasyManuals Logo
Home>Manitowoc>Ice Maker>Q270

Manitowoc Q270 User Manual

Manitowoc Q270
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
58 Part Number STH039 8/13
Safety Limit Notes
A safety limit indication is completed before the
water pump starts. Water contacting the ice
thickness probe in the freeze cycle will cause the
harvest light to flash. Do not mistake a harvest light
flashing in the freeze cycle with a safety limit
indication.
A continuous run of 100 harvests automatically
erases the safety limit code.
The control board will store and indicate only one
safety limit – the last one exceeded.
If the toggle switch is moved to the OFF position
and then back to the ON position prior to reaching
the 100-harvest point, the last safety limit
exceeded will be indicated.
If the harvest light did not flash prior to the ice
machine restarting, then the ice machine did not
stop because it exceeded a safety limit.