TECHNICAL SPECIFICATIONS AND INSTALLATION REQUIREMENTS
KW
14.6 kW
Power
AMP
70 Amp
Breaker
Works with
Low Pressure
German
Technology
V
220V - 240V
Overtemp
Protection
Non-Corrisive Micro-Chip
Computer
No PreheatMultiple Points
Of Use
50ft Max Distance
To Point of Use
MAX
Digital Panel
Voltage
Power
Min. Required
Circuit Breaker Size
Max. Amperage
Recommended Wire Size
Min. Water Flow
to Activate the Unit
Safe Operating Pressure
Water Connections
Installation
Temperature Setting
Dimensions
Weight
PRODUCT CODE
ECO150 | GPM
ECO150
208V - 240V
11kW - 14.6kW
70A
Double Pole Breaker
60.8A
6 AWG
0.53 GPM / 2L/min
5 PSI - 85 PSI
½" NPT
Mounted Vertically
Digital Panel
8.7" X 14.2" X 3.5"
10.1 lbs
1.0
1.5
2.0
2.5
3.0
3.5
98°F
68°F
51°F
41°F
34°F
29°F
Temp. Increase
per GPM
Voltage PowerMax. Amperage
208V 11.0kW53A
220V 12.3kW56A
240V 14.6kW61A
*Gallons per minute indicated on the
Temperature Increase table are
calculated assuming an outlet tempera-
ture of 105°F. Variable factors such
alternate incoming water temperature
or incorrect installation may yield
dierent results.
08