Energy
Minimum Required Circuit Breaker
Max. Amp. Load
Min. Wire Size
Voltage/Frequency
Water Connections
Recommended Min. Flow Activation
Safe Operating Pressure
Dimensions
Weight
*Wire gauge varies by amperage and distance; must contact electrician if you are not sure.
240V, 60Hz
3/4” NPT
0.85 GPM / 3.2 L/min
5 PSI - 85 PSI
11.0” x 16.1” x 3.5”
27kW
3x50A
112.5A
3x6
AWG Copper
18kW
2x50A
75A
2x6
AWG Copper
17.7 lbs 18.3 lbs
PRODUCT CODE ECO180 ECO270
ECO270
ECO180
TECHNICAL SPECIFICATIONS AND INSTALLATION REQUIREMENTS
*Gallons per minute indicated on the Temperature Increase table are calculated assuming an
outlet temperature of 105°F. Variable factors such alternate incoming water temperature or
incorrect installation may yield dierent results.
GPM
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
6.0
6.5
103°F
82°F
61°F
49°F
41°F
35°F
31°F
28°F
-
-
184°F
123°F
92°F
74°F
61°F
53°F
46°F
37°F
31°F
28°F
Temp. Increase
per GPM
ECO180 ECO270
KW
18 kW
Power
AMP
2x50 Amp
Breaker
KW
27 kW
Power
AMP
3x50 Amp
Breaker
240V
V
Multiple Points
Of Use
50ft Max Distance
To Point of Use
MAX
Digital Panel Non-Corrisive
German
Technology
Overtemp
Protection
Works with
Low Pressure
No Preheat Micro-Chip
Computer