1716
16L units
IMPORTANT  WARNING  -  PLEASE  TAKE  NOTE
 
If  your  unit is a 16L model, you MUST follow this diagram for correctly  connecting  
water  and  gas  to  the  unit.
 
The  water  and  gas connection diagram contained on the previous page  accurate 
only  for  the  5L  and 10L  Power  Gas  models.  If  you  have  a  5L  or  10L  unit,  please 
follow  the  diagram  contained  on  the  previous  page.
Water inlet pipe
Gas inlet pipe
Hot water outlet pipe
Drawing 08
*With and without LCD panels.
Note: If your gas model features an LCD panel, the digital display will indicate the outgoing 
water temperature.
This information is intended  as  a  guideline  based  on  typical residential environments.   
Temperature increases will vary depending on the environment in which the heater is used. 
Variables such as very low incoming water temperature or higher than average gas pressure 
can result in higher temperature increases. Higher incoming water temperature or lower 
than average gas pressure can result in lower temperature increases. ALWAYS test the 
water with your hand to confirm suitable temperature before use.
Temperature increases listed are based on use of the water heater under optimal conditions 
with an incoming water temperature of 48ºF. Variable factors such as  incorrect or imperfect 
installation or warmer incoming water temperature may yield different results.
* No need for electricity, starts with pulse ignition, powered by 2 D cell batteries.
Hot Water Outlet per Minute
Heat Loss
Exhaust Discharge Mode
Ignition
Energy Efficiency
Width x  DepthHeight x 
Weight
Aplicable Water Pressure
5 LPM / 1.3 GPM
34,614 BTU/h
11,4" x  4,7"17" x 
11 lbs
10 LPM / 2.7 GPM
79,228 BTU/h
Flue Duct Type
54% - 87%
13,6" x   6,9"23,6" x 
21 lbs
3.6 - 145.0 PSI / 0.25 - 10 bar
2D Cell Battery Powered (not included)
16 LPM / 4.2 GPM
111,903 BTU/h
6,5" x  8,2"27,9" x 1
29 lbs
Related Gas Pressure (PSI)
0.25 up to 0.5 PSI  (NG) & 0.4 (LPG)
Gas Type
Liquid Propane Gas or Natural Gas
Activation Flow Rate
Maximmum Flow Rate
2 GPM 3.1 GPM
4.3 GPM
10 PSI 10 PSI 10 PSI
TECHNICAL SPECIFICATIONS 
GAS 5L GAS 10L GAS 16L
Gas
Setting
Highest
Lowest
GA5L
GA10L
GA16L
Model
Highest
Lowest
Highest
Lowest
0.5
GPM
1.0
GPM
1.5
GPM
2.0
GPM
2.5
GPM
2.7
GPM
3.0
GPM
3.5
GPM
4.0
GPM
4.3
GPM
129º
34º
-
68º
-
88º
64º
17º
100º
34º
143º
44º
43º
11º
67º
23º
95º
29º
32º
9º
50º
17º
71º
22º
-
-
40º
14º
57º
18º
-
-
37º
13º
52º
16º
-
-
30º
9º
48º
15º
-
-
-
-
41º
13º
-
-
-
-
36º
11º
-
-
-
-
33º
10º
*Highest gas setting: set for Winter/High
*Lowest gas setting: set for Summer/Low
TEMPERATURE INCREASE PER GPM