3. Lock the metal plate B on ceiling mounted hanger
Caution: (1) Please use the hanger that has obtained UL security approval
(2) Please reserve the hole for the connecting wires of the camera
4. Combine the metal plate A and the metal plate B
(1) Push the metal plate A up to the ceiling and then to the right to latch the metal
plate B
(2) And then secure with 2 M3 silver screws and 1 M3 black screw
4.2.2.7 How to remove
1. Remove the connecting wires from the camera
2. Uninstall the camera together with the ceiling, loosen the three screws that fix the
metal plates A and B and push to the left to remove the machine
3. Then remove the screws on the hanger and the machine
black
screw
Marshall
4.3 Connecting devices
4.3.1 Connecting to PC (video conference)
SDI supports the audio output of 48 KHz / resolutions up to 1080p 59.94/50
4.3.2 Connecting to an HDTV/computer monitor (HDMI)
HDMI Cable
Or
SDI Cable
MTU
HDMI cable