10 MAC Quantum Profile Safety and Installation Manual
Connecting to an AC mains power source
The power cable can be hard-wired to a building installation circuit or fitted with a mains plug (cord cap) to
allow connection to local AC mains power outlets. If you install a mains plug, install a grounding-type
(earthed) plug, following the plug manufacturer’s instructions. Table 1 shows some possible mains power pin
identification schemes; if the pins are not clearly identified, or if you have any doubts about proper
installation, consult a qualified electrician.
Applying power
See Figure 7. To apply power to
the MAC Quantum Profile, check
that the tilt lock is released, that
the base is held securely, and that
personal safety will not be put at
risk when the fixture lights up and
moves, then set the power on/off
switch B to I (On).
Check that the mains power on/off
switch B is set to O (Off) before
inserting or removing the power
input connector at the input
socket A, otherwise you may
cause arcing at connector
terminals that can damage them.
Wire Color (US) Wire Color (EU) Pin Symbol Screw (US)
black brown live L yellow or brass
white blue neutral N silver
green yellow/green ground (earth) or green
Table 1: Cord cap (mains plug) connections