What to do if Martin MAC Encore Performance CLD fixtures respond erratically to the controller?
- JjoneswandaAug 2, 2025
If your Martin DJ Equipment fixtures reset correctly but respond erratically or not at all to the controller, first inspect connections and cables, correcting any poor connections and repairing or replacing damaged cables. If the issue persists, insert a DMX termination plug in the data output socket of the last MAC Encore™ Performance on the data link. Also, verify the fixture address and protocol settings. Finally, one of the fixtures may be defective and disturbing data transmission on the link. To check this, unplug the XLR in and out connectors and connect them directly together to bypass one fixture at a time until normal operation is regained. If you identify a defective fixture, have it serviced by a qualified technician.