3% of reading +8 graduation )
Overload protection: self-recovery fuse (F500mA/250V)
4.2.9 Temperature
Range
Resolution
Accuracy
-20
℃
~0
℃
±
(5.0% of reading +4 graduation)
1
℃
~400
℃
± (
1.0% of reading +3 graduation)
401
℃
~1000
℃
1
℃
±
2.0% of reading
* Error of thermoelectric couple is not included in temperature
parameters.
Overload protection: self-recovery fuse (F500mA/250V)
4.2.10 DC Current
Range
Resolution
±(
2.0% of reading +5 graduation)
Overload protection: self-recovery fuse (F500mA/250V); No
fuse protection for the range of 10A.
Max. input current: mA
:
DC 200mA or AC (effective value);
10A
:
DC 10A or AC (effective value)
When measuring current which is greater than 5A, do not
conduct measurements consecutively for more than 4
minutes. After the measurements are completed, do not
conduct new current measurements until 10 minutes later.
4.2.11 AC Current
Range
Resolution
Accuracy
200mA 0.1mA
±(
1.8% of reading + 3 graduation)
10A 10mA
±(
3.0% of reading + 7 graduation)
Overload protection: self-recovery fuse (F500mA/250V); No
fuse protection for the range of 10A.
18
Max. input current: mA: DC 200mA or AC (effective current);
10A: DC 10A or AC (effective
current)
When measuring current which is greater than 5A, do not
conduct measurements consecutively for more than 4
minutes. After the measurements are completed, do not
conduct new current measurements until 10 minutes later.
Frequency response: 40Hz-400Hz, sine wave effective value
(mean value response)
5. Meter Maintenance
Basic maintenance information is given in this section,
including instructions for replacing a fuse and replacing a
battery.
Do not try to repair the meter unless you are an experienced