System Description:
The Simplus tank has a Logix top mounted automatic control valve
with an electronic time clock to initiate regeneration. The Logix Valve
is constructed of non-corrosive Noryl material and is rated at a maximum
working water pressure of 100 psi. It uses a 742 microprocessor based
timer to actuate regeneration in the following ways:
a. Manual regeneration button
b. Regeneration day setting
Simplus Positioning:
1. Place Filter in desired position, far enough from walls and other
obstructions to allow for servicing the unit.
2. Place the Filter within reasonable access to a grounded 115V/60 HZ
circuit and a legal drain line connection.
Simplus Tank Loading:
1. Remove yellow caplug from top of tank. DO NOT CUT white riser tube.
Tube was prefitted at the factory.
2. The distributor is permantly attached to the vortech----centering is not
necessary. The top of the distributor will extend above the top of the
tank (this was prefitted at the factory).
3. Cover the top opening of the distributor pipe before filling the tank with
media.
4. Pour all filter media provided with the unit into the top of the tank. See
page one for your specific model number of unit to determine the
amount of media to load into the mineral tank.
5. Remove the material used to cover the top opening of the distributor
pipe.