STOPPING THE GENERATOR
To stop the generator:
1. Turn off, and then unplug all connected electrical devices.
2. Switch the circuit breaker to the "OFF” position.
3. Allow the generator to run for several more minutes with no electrical devices connected. This
helps stabilize the temperature of the generator.
4. Set the engine switch to the "OFF” position.
5. Turn the fuel valve to the "OFF” position.
WARNING: Allow the generator to cool for several minutes before touching areas that
become hot during use.
CAUTION: Allowing gas to sit in the generator tank for long periods of time without use can
make it difficult to start the generator in the future. Never store generator for extended periods
of time with fuel in the tank.
MAINTENANCE
Proper routine maintenance of your generator will help prolong the life of your machine. Please
perform maintenance checks and operations according the schedule in figure 13.
CAUTION: Never perform maintenance operations while the generator is running.
Recommended Maintenance Schedule
Each
use
Every
month or
20 hrs
Every 3
months or
50 hrs
Every 6
months or
100 hrs
Every
year or
300 hrs
Engine oil
Check level
×
Replace
×
Air cleaner
Check
×
Clean
×
Fuel filter cup
Clean
×
Spark plug
Check/clean
×
Gas tank
Check Gas
Level
×
Clean
× ×
Figure 13 - Recommended Maintenance Schedule
Cleaning the Generator
Always try to use your generator in a cool dry place. However, in the event your generator becomes
dirty, you may clean the exterior with one or more of the following:
- A damp cloth
- A soft brush
- A vacuum
- Pressurized air
16