Disconnect the spark plug.
Do not obstruct any ventilation openings.
Keep the generator in a cool dry area.
LONG TERM STORAGE
It is important to prevent gum deposits from forming in essential fuel system parts such as the
carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels
(called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of
acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid
engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:
Add a quality gasoline stabilizer to the fuel per the specifications, and run the unit for 10-15
minutes.
After engine cools down, remove all gasoline from the fuel tank.
TROUBLESHOOTING
Problem Cause Solution
Engine switch is set to “OFF”. Set engine switch to “ON”.
Fuel valve is turned to “CLOSED”. Turn fuel valve to “OPEN” position.
Choke is open. Close the choke
Engine is out of gas. Add gas.
Engine is filled with contaminated
or old gas
Change the gas on the engine.
Spark plug is dirty. Clean spark plug.
Spark plug is broken. Replace spark plug.
Generator is not on a levelled
surface.
Move generator to a levelled surface to
prevent low oil shutdown from triggering.
Engine will
not start.
Oil is low Add or replace oil.
Circuit breaker is off. Set the circuit breaker to the “ON”
position.
Bad connecting wires/cables. If you are using an extension cord, try a
different one.
Engine runs
but there is
no electrical
output.
Bad electrical device connected to
generator.
Try connecting a different device.
Generator is overloaded.
Try connecting fewer electrical loads to
the generator.
Short in one of the connected
devices.
Try disconnecting any faulty or
short-circuited electrical loads.
Generator
runs but
does not
support all
electrical
devices
connected.
Air cleaner is dirty. Clean or replace air cleaner.