TROUBLE SHOOTING
8 TROUBLE SHOOTING
Malfunction Possible cause What to do
No output voltage and/or current No AC mains or fuse blowes Check fuse, replace if necessary.
Mains or generator output too low Check input voltage, must be between
190 and 260V (nominal 230V).
Output voltage too low but Battery load consumes more than the Reduce the battery load taken from
charger supplies max. current charger can supply, the battery voltage batteries.
cannot increase more
Batteries not 100% charged Measure the battery voltage after a
while, this will be higher.
Charge current too low Batteries almost fully charged Check if the charger is in the absorp-
tion mode. In this mode, the charge
current will slowly decrease.
High ambient temperature If the ambient temperature is more than
40°C, the maximum charge current
automatically will be reduced.
Mains too low When the mains is lower than 190V,
the charger will regulate the current
down.
Batteries not fully charged Charge current too low See “charge current too low”;
Current to load too high Decrease the battery load;
Charge time too short Increase type of charger;
Battery temperature too low Use temperature sensor;
Defective battery (short circuit in cell) Replace the battery;
Defective battery charger Check the charger.
Battery very fast empty Battery capacity reduced because:
• wastage Replace the batteries;
• sulphating/stagnation Charge/discharge for several times, this
might help, otherwise replace batteries.
Batteries are warm/gassing Defective batteries (short circuit in cell) Replace batteries;
Battery temperature too high Use temperature sensor;
Charge voltage too high Check jumper ‘battery isolator
on front panel.
If you cannot solve the problem with this fault finding table, contact your Mastervolt Service Centre.
For a detailed distributor list, please contact our main office in Amsterdam, tel. +31-20-3422100.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mastervolt MASS 12/30-2 and is the answer not in the manual?

Mastervolt MASS 12/30-2 Specifications

General IconGeneral
BrandMastervolt
ModelMASS 12/30-2
CategoryBattery Charger
LanguageEnglish

Related product manuals