34
8.5 ERROR CODE TROUBLESHOOTING - 0140 / 01B2
CHAPTER 8: TROUBLESHOOTING
ERROR CODE 0140 or 01B2
1)  SYMPTOM:
   a.  0140 - Incline motor operation has failed. 
   b.  01B2 - The incline motor has no action or current.  
2)  SOLUTION:
   a.  Run Auto Calibration (see Section 4.8), then check the LCB LEDs.  If the incline LED is not a solid light (only one LED will show a solid 
light at a time), replace the LCB (Figure A).  
   b.  If the LCB incline LEDs are solid, use a multi meter to check the fuses.  They should have an ohm reading of 0 (Figures B & C).  
   c.  If the LCB incline LEDs are solid, and the fuses check out ok, run auto calibration.  
     - If auto calibration does not resolve the issue, replace the incline motor.  Then re-run auto calibration.  
FIGURE A
FIGURE B
FIGURE C
1
2