35
ERROR CODE 01A0
1) SYMPTOM:
a. 01A0 - Incline motor disconnected.
2) SOLUTION:
a. Check the Machine Type in Service Mode.
b. Check the connection of the incline motor at the LCB.
c. Run auto calibration (see Section 4.8).
d. If auto calibration fails, re-enter Engineering Mode and again go to Calibration.
- Measure the incline VR value (Figure A) by measuring across the Blue / Orange and Brown / Orange wiring in the incline motor wire
harness. The VR range should be 0.5k - 9.5k ohms (for example if the circuit is open or shorted). If the VR is outside of this range, replace the
incline motor.
e. If the incline motor does not resolve the issue, replace the LCB. NOTE: Run auto calibration if the incline motor or LCB is replaced.