24
Calder Brothers Corp
V1.0
Serial Number Range:
848-S-56TCG9Y2*03848 to _____________
Page 24
Model: 1560 Paver
Stop engine. Wait 15 minutes or engine oil to cool before proceeding.
On the hopper side, remove drain plug and position capturing bucket.
Drain crankcase.
Unscrew and discard existing lters.
Fill new elements with fresh oil.
Lightly coat the seal rings with oil, and then screw on lters until seals meet anges.
Tighten an additional 1/2 to 3/4 turns by hand.
IMPORTANT: Do not over tighten.
Fill crankcase to correct level.
Start engine and run at low idle. Have an assistant visually check seal areas for leaks.
Stop engine. Wait a few minutes, and then check engine oil level once again.
Hydraulic System
DANGER: RELEASE, RESTRAIN, OR OTHERWISE RENDER SAFE ALL POTENTIAL HAZARD-
OUS STORED OR RESIDUAL ENERGY. IF A POSSIBILITY EXISTS FOR REACCUMULATION OF
HAZARDOUS ENERGY, REGULARLY VERIFY DURING THE SERVICE AND MAINTENANCE THAT
SUCH ENERGY HAS NOT REACCUMULATED TO HAZARDOUS LEVELS.
DANGER: DO NOT RELEASE OR OPEN ANY HOSE OR HYDRAULIC CIRCUIT WHILE ANY IM-
PLMENT IS SUSPENDED IN THE AIR. ENSURE ALL IMPLMENTS ARE PROPERLY SUPPORTED
AND/OR IN THEIR DOWN MOST LOWEST POSITION.
1. Hydraulic Fluid Change
a. Stop engine. Allow system pressure to drop and remove ller cap.
b. Remove drain plug and drain system completely.
c. Remove hydraulic lter. Replace lter element and reinstall.
d. Replace uid to approximately 1” from top of reservoir.
Operate paver and recheck level.
e. Check visually for oil leaks.
NOTE: Each paver should be thoroughly inspected after each use and during maintenance
cycle for:
Tightness of mounting bolts and attaching hardware on bearings, couplings, frame, etc.
Leaks, cracks and loose electrical and uid ttings.
Malfunctioning indicators or controls.
Cleanliness.