51
INSTALLATION
www.maxcessintl.com MAGPOWR CL Load Cells MI 850A192 J 1
Mechanical and
electrical installation
CAUTION Possible damage to load cell.
Do not hammer on the load cell.
CAUTION Possible damage to load cell.
Do not disassemble the load cell; there are no serviceable parts
inside.
WARNING Danger of injury from crushing.
Maintenance and repair tasks on the load cell device must be
performed only when the machine has been stopped and has
been secured from being turned on again.
Mounting
1. Remove the envelope containing 4 set screws from the bore
and install into sensor as shown in
Figure 1
.
2. Select a clean flat surface where the wrap angle of the web
does not change.
3. Locate the centerline of the CL load cell mounting holes, so
that it bisects the wrap angle of the web.
4. Fasten with two cap screws making sure the cap screw
penetration does not exceed dimension 'N' shown on the
outline dimension drawing (
page 4-1
).
Figure 1. Mounting