8.1 General alarm indications displayed on the control panel causes and solutions
This section shows the machine alarms, which can be viewed on the digital display, together with possible causes and solutions.
FAULT/
PROBLEM
INSTRUCTIONS
FOR THE OPERA-
TOR
POSSIBLE CAUSES
SOLUTIONS
!“P-alarm warning:
The refrigeration tank temperature
probe is faulty (interrupted or out of
tolerance) and/or its wiring is dam-
aged. The probe indicates a temper-
ature higher than the safety limits.
Contact the Technical Assistance Service.
!“PE” alarm warning:
The refrigeration tank temperature
probe is faulty (short-circuited) and/
or its wiring damaged. The probe
indicates a temperature lower than
the safety limits.
The control circuits do not allow
disconnection of power for the
compressor (which keeps operat-
ing). The related control contactor
is probably jammed.
Contact the Technical Assistance Service.
Contact the Technical Assistance Service.
!