EasyManua.ls Logo

Maxima 2 - Maintenance Sheets

Maxima 2
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
DO NOT PUT GASKETS IN THE INDUSTRIAL DISHWASHER, AS THE HIGH TEMPERATURES
COULD DEFORM THEM, MAKING THEM UNUSABLE.
Air regulator gaskets:
FOR CORRECT GASKET CLEANING, USE A DISPOSABLE CLOTH AND A
DETERGENT FOR ITEMS AND MACHINES USED FOR FOOD PREPARATION.
7.4 Maintenance sheets
Replacing the gaskets S01
CHECKING INTERVAL: 500 hours or quarterly
AUTHORISED OPERATOR: 1 Operator
TIME NEEDED: 5 minutes
TOOL: Non-metallic pointed tool
- Regularly check the integrity of the gaskets and substitute them if they are broken, worn or swollen.
- Only use original gaskets, made of food-safe rubber.
- A full spare set of all gaskets is supplied with the machine, plus a tube of food-safe grease for lubricating them.
Remove the air regulator from the pump cover and take out the worn
gaskets using a non-metallic pointed tool, taking care not to damage
the housing.
Eliminate any product residues from the housings and fit the new
gaskets, lubricating them with the food-safe grease supplied.
Refit the air regulator on the pump cover.
Valve holder and air adjustment valve gaskets:
Unscrew the air regulator knob by turning it in an anticlockwise di-
rection and slide out the valve holder and regulator valve vertically.
Remove the worn gaskets from the valve holder and valve using a
non-metallic pointed tool, taking care not to damage the housing.
Eliminate any product residues from the housings and fit the new gas-
kets, lubricating them with the food-safe grease supplied. Reposition
the valve holder and valve in the air regulator and screw on the knob.

Table of Contents