GEN
When the user uses the device to connect the
generatorselect the generator mode.
03
Output voltage
Set the output voltage (220VAC-240VAC)
04
Output frequency
50HZ(default)
60HZ
05
Solar supply
priority
Solar energy provides power to charge battery as
first priority
(default)
Solar energy provides power to the loads as first
priority
06
Overload bypass:
When enabled,
the unit will
transfer to line
mode if overload
occurs in battery
mode.
Bypass disabled
Bypass enabled
(default)
07
Auto restart
when overload
occurs
Restart disabled
(default)
Restart enabled
08
Auto restart
when over
temperature
occurs
Restart disabled
(default)
Restart enabled
10
Charger source
priority: To
configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first
Solar energy will charge battery as first priority.
AC will charge battery only when solar energy is
not available.
Solar and AC
(default)
Solar energy and AC will charge battery at the
same time.
Only Solar
Solar energy will be the only charger source.
If this inverter/charger is working in Battery mode or Power saving
mode, only solar energy can charge battery. Solar energy will charge
battery if it's available and sufficient.
11
Maximum
charging current:
To configure total
charging current
40A (default)
Setting range is from 1 A to 70A.
Increment of each click is 1A.