When the user uses the device to connect the
generator,select the generator mode.
Set the output voltage (220VAC-240VAC)
Solar energy provides power to charge battery as
first priority
Solar energy provides power to the loads as first
priority
Overload bypass:
When enabled,
the unit will
transfer to line
mode if overload
occurs in battery
mode.
Auto restart
when overload
occurs
Restart disabled
(default)
Auto restart
when over
temperature
occurs
Restart disabled
(default)
Charger source
priority: To
configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar energy will charge battery as first priority.
AC will charge battery only when solar energy is
not available.
Solar energy and AC will charge battery at the
same time.
Solar energy will be the only charger source.
If this inverter/charger is working in Battery mode or Power saving
mode, only solar energy can charge battery. Solar energy will charge
battery if it's available and sufficient.
Maximum
charging current:
To configure total
charging current
Setting range is from 1 A to 70A.
Increment of each click is 1A.