Maximum Controls MAX 2200 PRO - Wiring Overview

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
CLOSINGOPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E 2/1 F
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN MIN
MAX MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14 12
9
7
UL SENSOR N.C.UL SENSOR 10K
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
Safety Opening Device
Safety Devices
Factory Wired
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
for SLIDE operator
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
External
Loop
Detector
External Loop
Detectors
Wire directly to
7-PIN terminal
Card Reader
Separate power for
devices if required.
KeypadKey Switch
Key Switch
Telephone Entry
Emergency OPEN
(Overrides gate
disable switch)
MAX OPEN
(Overrides gate
disable switch)
Emergency/Security Opening Devices
Normal
Opening
Devices
Dry Contact NO
Dry Contact NO
NO
NO
Radio Signal
Radio Signal
Radio Gnd
12 VDC OR 24 VDC
Radio Power
250 mA Max.
4-Wire
Radio
3-Wire
Radio
Normal
Opening
Device
RS-485 Communication
Secondary Operator
Stop
Stop
Close
Open
Tamper NO
Tamper IN
Com
Com
Com
Gate Disable
Com
Gnd
Gnd
Gnd
Gnd
Gnd
Manual Release
Manually Releases
Slide Gate
Gnd
Gnd
Gnd
NO
NC
Power
NC
Jog Left
Jog Right
External Alarm
Reset Button
Dry Contact
Security Device
PRESS
to RESET
ID Plug:
Specific for operator
type REQUIRED.
Maglock
Solenoid
Lock
Motion Sensor
External Jog Left/Right
Key Switch
Opening
Direction
Security
Camera
page 15
page 18
page 15
see page 17
see page 12
see page 12
see page 12
see page 12
see page 7-8
see page 6
see page 11
see page 10
3-Button Control Station
Dry Contact
Gate Disable Switch
ON
OFF
Security Devices
Security Device
Opening Device
Security
Devices
Entrapment Protection Devices
Safety Device
Normal Opening Device
Siren
Warning
Light
Power
Power
Power
Existing
Building
Alarm
System
Timer
Normally Closed
Photocells
Closing
Direction
Opening
Direction
Closing
Direction
10K
Sensing
Edges
IMPORTANT: Sensing devices
MUST be powered by Matrix III or
they will NOT be MONITORED.
IMPORTANT: Photocells MUST
be in alignment or fault will occur.
GATE OPEN
GATE CLOSED
Gate Status
Monitoring Device
Power
Bi-parting gates using locks:
Primary gate opens FIRST. Install
lock accordingly to account for this.
O
N
1
2
3
4
5
6
7
8
5 =
Optimum
Sens.
= Increase Sens.
= Decr
ease Sens.
DEFLECTOMETER
POWER
ON
=
No
rmal Power
OFF= No Power
LED INDICATORS
DE
TECT
ON
=
De
tect
OFF= No Detec
t
2
H
z Fl
as
h
=De
l
ay
Ti
m
i
ng
SW1
S
W
2
Freq
ue
nc
y
ON ON
= Low
ON OFF
= Med
i
u
m-Low
OFF ON
= Medium-High
OFF OFF
= Hi
g
h
SW4
S
W
5
Outpu
t
B
ON
ON
=
P
uls
e
on
E
n
try
ON OF
F
=
B
s
ame
a
s
A
O
FF
O
N = P
u
ls
e
o
n
Ex
it
OFF
O
F
F
= Lo
o
p
F
a
u
lt
SW3
ON
= Fail
Secure
OFF =
Fa
i
l
S
a
fe
SW6
ON
= 2
S
econd
Delay
O
F
F
=
No Dela
y
SW7
ON
=
N
o
r
m
a
l P
rese
n
ce
O
F
F =
Infi
n
ite
P
r
es
ence
S
W
8
O
N
=
Se
n
s
iti
v
ity
B
o
o
s
t
OFF
=
N
o
S
e
n
s
itiv
ity
B
oos
t
Loo
p Fa
ul
t
1 Flash = Op
en L
oo
p
2 F
l
as
he
s=
S
hort
ed
Lo
o
p
3 Flashes
=25%
ch
ange
of
Induct
ance
Both LED’s
Flash
i
ng=
Cu
rrent
Lo
o
p
Fau
l
t
PWR
LED
Fl
as
hi
ng=
Pr
ev
i
ou
s L
oop
Fault
EDI
Te
l: 480.968.6
407
DEFLEC
T
O
METER
SENS
R
E
SET
PO
WER
D
E
T
E
CT
EDI
S
ENS
LMA1800
OPTIONS
1
2 3
4
5 6 7 8
O
N
Plug-In Loop
Detectors
In-Ground Loop Connections
Loop Detector Rack
SAFETYCENTEREXIT
SAFETYCENTEREXIT
In-Ground Loops
Safety Loops
Wired in series
Safety
Loop
Safety
Loop
Exit
Loop
page 11
page 10
page 11
page 6
page 6
page 11
page 9
page 19
page 13
page 10
12V Power
Stand-Alone
Keypad
less than 200 mA
+
+
-
+
-
-
1700 FS
O
R
P
32
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7d
wiring overview

Related product manuals