PAGE 23
OIL CHANGE INSTRUCTIONS
1. Place an empty 3 Gallon Container under
the Drain Plug.
NOTE:
Determine if your unit is Gravity Down or Power Down
before choosing the method of oil change.
GRAVITY DOWN UNITS
2. Remove the Drain Plug and activate the
switch to “Lower” the
unfolded Platform
3. Replace the Drain Plug. Remove the
Filler/Breather Cap and fill the Reservoir to within 1” from the top.
4. Replace the Filler/Breather Cap.
POWER DOWN UNITS
DRAIN
PLUG
1. Place an empty 3 Gallon Container under the Drain Plug.
WHITE
WIRE
2. Raise the Platform and remove the Drain Plug.
3. Remove the “White Wire” from the Motor
Solenoid and activate the switch to “Lower”
the Platform.
4. Replace the Drain Plug and White Wire.
Remove the Filler/Breather Cap and fill the Reservoir
to within 1” from the top.
5. Replace the Filler/Breather Cap.
FILLER/BREATHER
CAP
OIL SPECIFICATIONS
Grade ISO - (32)
Gravity, API - 29.5 Degrees
Pour Point, F - (-54 Degrees)
VISCOSITY
@ 40 Degrees C - 31.2 cSt
@ 100 Degrees C - 6.2 cSt
VISCOSITY INDEX - 154 VI
Flash Point, F - 325 Degrees