FOLDING CYLINDER REPLACEMENT
1. Lower the Platform to the ground.
2. Disconnect and plug the Hydraulic Hose from the lower part of the Cylinder
(for cleanliness).
3. Remove the Lower Roll Pin from the Inside Coupling and then remove the
Lower Cylinder Pin.
4. Remove the Upper Roll Pin from the Runner Weldment and then remove
the Upper Cylinder Pin.
5. Replace the Cylinder and reverse these steps for re-assembly.
NOTE:
Be sure the new Cylinder has a 1-3/4” Outside Diameter Rod
End. This will ensure that the correct cylinder is being used.