15
7. Bolt cover on the main housing 
as shown in FIG. 15-3. Torque 
the 5/16”-18 cover bolts from 
10 to 14 lb-ft.
CAUTION
Main housing cover must be 
correctly secured to prevent it 
from becoming a hazard. 
POWER UNIT
(MANUAL CLOSE POWER UNIT SHOWN)
FIG. 15-2
POWER UNIT
(REF)
RESERVOIR
5. Raise platform to bed height (FIG. 15-1). 
Continue to hold UP/DOWN control 
switch for 30 - 60 seconds to circulate 
hydraulic fl uid through slave cylinder 
and reservoir (FIG. 15-2). Release UP/
DOWN control switch.
PLATFORM AT BED HEIGHT 
FIG. 15-1
NOTE:
  One cycle of draining, fi lling, 
and circulating hydraulic fl uid 
should be enough to fi ll the sys-
tem with new hydraulic fl uid.
6. Lower platform to the 
ground (FIG. 15-3). 
BOLTING ON COVER
FIG. 15-3
UP/DOWN 
CONTROL 
SWITCH
BOLT,  
LOCK WASHER & 
FLAT WASHER
(3 PLACES)
COVER