19
Never move the vehicle unless the Liftgate is properly stowed.
6. Before moving the vehicle,
prepare the Liftgate as fol-
lows. Make sure load is
removed from platform. If
platform is at bed level, lower
the platform to ground level
as follows. Hold the external up-
down toggle switch in the DOWN
position (FIG. 19-1) until platform
is on the ground (FIG. 19-2).
WARNING
!
7. Ensure retention ramps
are stowed. (See LOADING
OR UNLOADING PLAT-
FORM.) Then, fold the ip-
over (FIG. 19-3).
Never operate control switch
while folding the ipover.
WARNING
!
PLATFORM LOWERED TO GROUND
FIG. 19-2
FOLDING FLIPOVER
FIG. 19-3
FLIPOVER
NOTE: If necessary, release the toggle switch to stop the platform
from moving.
DOWN SWITCH
FIG. 19-1
UP-DOWN
TOGGLE SWITCH