11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
18
STEP 6 - INSTALL CONTROL SWITCH - Continued
4. Open the Pump Box Cover.
Connect the RED, BLACK,
GREEN, and WHITE wires
from the Control Switch cable
to Pump Wiring as shown in
FIG. 18-1.
CONNECTING CONTROL SWITCH
CABLE TO PUMP WIRING
FIG. 18-1
WHITE WIRE GREEN WIRE
BLACK WIRE
RED WIRE
CRIMP
TERMINALS
“A” VALVE
“A” VALVE
WIRE
“E” VALVE
“E” VALVE
WIRE
NOTE: MAXON recommends using dielectric
grease on all electrical connections.
NOTE: An extra crimp-on connector is supplied
with the RED wire and BLACK wire on
the Control Switch cable. Crimp each
of the extra connectors to the correct
wires shown in the illustration.