CHANGING HYDRAULIC FLUID
3. Disconnect the white wire (FIG. 15-2) from starter 
solenoid. Lower the platform while draining the 
remaining hydraulic fl uid from system. Reinstall 
drain plug. Reconnect the white wire to starter 
solenoid.
2. Open and raise platform to vehicle bed height. 
Pull out (no threads) drain plug (FIG. 15-1). Drain 
hydraulic fl uid.
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic system. 
Before opening the hydraulic fl uid reservoir fi ller cap, drain plug and hydrau-
lic lines, clean up contaminants that can get in the openings. Also, protect the 
openings from accidental contamination. 
POWER DOWN LIFTGATES
1. Remove the pump cover (FIG. 13-1). Place empty 
5 gallon bucket under drain plug (FIG. 15-1).
4. Pull out (no threads) fi ller cap (FIG. 15-1) and 
refi ll reservoir with hydraulic fl uid to level shown 
in FIG. 15-1. Reinstall fi ller cap (FIG. 15-1).
1. Remove the pump cover (FIG. 13-1). Place empty 
5 gallon bucket under drain plug (FIG. 15-1).
GRAVITY DOWN LIFTGATES
2. Lower platform to ground. Pull out (no 
threads) drain plug (FIG. 15-1). Drain hydrau-
lic fl uid from system. Reinstall drain plug.
3. Pull out (no threads) fi ller cap (FIG. 15-1) 
and refi ll reservoir with hydraulic fl uid to 
level shown in FIG. 15-1. Reinstall fi ller 
cap (FIG. 15-1).
4. Bolt on the pump cover as shown in FIG. 16-1  
Torque the bolts (cap screws) to 10-14 lb-in. 
LIFTGATE SHOWN WITH GRAVITY 
DOWN PUMP & MOTOR
FIG. 15-1
DRAIN 
PLUG
POWER DOWN PUMP
FIG. 15-2
STARTER 
SOLENOID
WHITE 
WIRE
+50 to +120 Degrees F - Grade ISO 32  
 Below + 70 Degrees F - Grade ISO 15 or MIL-H-5606
NOTE: Liftgate is shipped with ISO 32 oil. Use correct oil for climate conditions.
See TABLES 14-1 & 14-2 for recommended brands of ISO 32 & ISO 15 oils. 
FILLER CAP
RESERVOIR
1-7/8” - 2-3/8” (GD)
2-5/8” - 3-1/8” (PD)