EasyManua.ls Logo

Maxon TE-15 - FORKLIFT ADVISORY

Maxon TE-15
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
13
CHECKING HYDRAULIC FLUID
1. With platform at bed height, check oil level
in the pump reservoir (FIG. 13-1). To add
oil, pull out ller cap (no threads) (FIG.
13-1). Add hydraulic oil in reservoir to the
level shown in FIG. 13-1.
2. Reinstall ller cap (FIG. 13-1).
Keep dirt, water and other contaminants from entering the hydraulic system.
Before opening the hydraulic uid reservoir ller cap, drain plug and hydrau-
lic lines, clean up contaminants that can get in the openings. Also, protect the
openings from accidental contamination.
FILLER CAP
RESERVOIR
PUMP RESERVOIR
(GRAVITY DOWN POWER UNIT SHOWN)
FIG. 13-1
1-7/8” - 2-3/8” (GD)
2-5/8” - 3-1/8” (PD)
3. Bolt on the pump cover as shown
in FIG. 13-2. Torque the bolts (cap
screws) to 10 - 14 lb-in.
BOLTING ON PUMP COVER
FIG. 13-2
NOTE: Liftgate is shipped with ISO 32 oil. Use correct oil for climate conditions.
See TABLES 14-1 & 14-2 for recommended brands of ISO 32 & ISO 15 oils.
NOTE: Hydraulic oil level must be mini-
mum of 1-1/2” above the bottom
of reservoir to operate Liftgate.
POWER UNIT
(REF)
PUMP COVER
CAP
SCREWS
(5 PLACES)
FLAT
WASHERS
(5 PLACES)
PUMP MOUNT
PLATE
CAUTION
+50 to +120 Degrees F - Grade ISO 32
Below + 70 Degrees F - Grade ISO 15 or MIL-H-5606

Other manuals for Maxon TE-15

Related product manuals