IOMM AGR AGR 055A through 100A 19
Table 12, 60 Hz Single Point Power, Field Wiring Data
Wiring to Standard Wiring to Optional
AGR Power Block Non-Fused Disconnect Switch
Unit Volts Terminal Connector Wire Range Terminal Connector Wire Range
Size Amps (Copper Wire Only) Amps (Copper Wire Only)
208 335 # 4 - 400 MCM 250 250-500 MCM
230 335 # 4 - 400 MCM 250 250-500 MCM
055A 380 335 # 4 - 400 MCM 150 #2 - 3/0
460 335 # 4 - 400 MCM 150 #2 - 3/0
575 335 # 4 - 400 MCM 100 #6 - 1/0
208 335 # 4 - 400 MCM 400 250 - 500 MCM
230 335 # 4 - 400 MCM 400 250 - 500 MCM
060A 380 335 # 4 - 400 MCM 250 #4 - 350 MCM
460 335 # 4 - 400 MCM 150 #2 - 3/0
575 335 # 4 - 400 MCM 150 #2 - 3/0
208 335 # 4 - 400 MCM 400 250 - 500 MCM
230 335 # 4 - 400 MCM 400 250 - 500 MCM
065A 380 335 # 4 - 400 MCM 250 #4 - 350 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 150 #2 - 3/0
208 335 # 4 - 400 MCM 400 250 - 500 MCM
230 335 # 4 - 400 MCM 400 250 - 500 MCM
070A 380 335 # 4 - 400 MCM 250 #4 - 350 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 150 #2 - 3/0
208 335 # 4 - 400 MCM 400 250 - 500 MCM
230 335 # 4 - 400 MCM 400 250 - 500 MCM
075A 380 335 # 4 - 400 MCM 250 #4 - 350 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 150 #2 - 3/0
208 840 (2 qty.) 1/0 - 600 MCM 400 250 - 500 MCM
230 840 (2 qty.) 1/0 - 600 MCM 400 250 - 500 MCM
080A 380 335 # 4 - 400 MCM 250 #4 - 350 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 250 #4 - 350 MCM
208 840 (2 qty.) 1/0 - 600 MCM N/A N/A
230 840 (2 qty.) 1/0 - 600 MCM N/A N/A
085A 380 335 # 4 - 400 MCM 400 250 - 500 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 250 #4 - 350 MCM
208 840 (2 qty.) 1/0 - 600 MCM N/A N/A
230 840 (2 qty.) 1/0 - 600 MCM N/A N/A
090A 380 335 # 4 - 400 MCM 400 250 - 500 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 250 #4 - 350 MCM
208 840 (2 qty.) 1/0 - 600 MCM N/A N/A
230 840 (2 qty.) 1/0 - 600 MCM N/A N/A
095A 380 335 # 4 - 400 MCM 400 250 - 500 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 250 #4 - 350 MCM
208 840 (2 qty.) 1/0 - 600 MCM N/A N/A
230 840 (2 qty.) 1/0 - 600 MCM N/A N/A
100A 380 335 # 4 - 400 MCM 400 250 - 500 MCM
460 335 # 4 - 400 MCM 250 #4 - 350 MCM
575 335 # 4 - 400 MCM 250 #4 - 350 MCM
All Electrical Data notes are on page 20