Page 16 SE
AC
Slab Series - Operator’s Manual
November 2022
Functions Test
DO NOT operate this machine until you have read and understood this manual, have
performed the Workplace Inspection,\ Pre-Start Inspection and Routine Maintenance, and have
completed all the test operations detailed in the Operating Instructions section.
This section provides instructions and tests for each function of machine operation. Follow all safety
rules and instructions. The operator must conduct inspections and a Functions Test of the machine
before each work shift to check that all machine systems are working properly.
Test the machine on a rm level surface with no debris, drop-o󰀨s, potholes or overhead obstructions.
Perform each step outlined in this section.
This machine shall only be operated by trained and authorized personnel. If multiple operators use
this machine, all must be trained, qualied and authorized to use it. New operators must perform a
Pre-Start Inspection and Functions Test prior to operating the machine.
Operators must comply with all employer and job site rules and governmental regulations regarding
the use of personal protective equipment.
DO NOT use a machine that is malfunctioning. If any function does not perform as described, tag the
machine and remove for repair by a qualied service technician. After repairs are completed, a Pre-
Start Inspection and Functions Test must be performed before using the machine.
Check the area above and around the machine for obstructions and
electrical power lines before operating the machine. The machine must
have space to allow full elevation of platform.
Prestart
ART_3353
Perform Prestart Inspection (see page 34).
Check Emergency Stop Switches at both the base and platform controls – turn
clockwise or pull to reset.
ART_5182
Main Power
Switch
1930SE
Check Main Power Switch. Must be in ON position.