Page 5 69 Series - Operator’s Manual
February 2019Section 3 - Safety Rules and Hazards
Safety and Hazards
Electrocution Hazards
This machine is not electrically insulated and will not provide
protection from contact with or proximity to electrical current.
Maintain safe distances from electrical power lines and
apparatus in accordance with applicable governmental
regulations and the following chart.
Voltage Minimum Safe Approach Distance
Phase to Phase Feet Meters
0 to 300V Avoid Contact
300V to 50kV 10 3.05
50kV to 200kV 15 4.60
200kV to 350kV 20 6.10
350kV to 500kV 25 7.62
500kV to 750kV 35 10.67
750kV to 1000kV 45 13.72
Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the
platform must not touch or operate the machine until energized power lines are shut off.
Do not operate the machine during lightning or storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials must not exceed the maximum platform capacity or the
maximum capacity of the platform extension.
Maximum capacity 3369 4069
Platform allowable maximum load 1000 lb 454 kg 800 lb 363 kg
Extension deck allowable maximum load 300 lb 136 kg 300 lb 136 kg
Work Area Safety
Do not raise the platform unless the machine is on a firm, level
surface.