Page 24 Micro19 - Service & Parts Manual
October 2021Section 10 - Maintenance
Clean the inside of the hydraulic tank using a mild solvent. Allow the tank to dry completely.
Install the hydraulic tank and install and tighten the hydraulic tank retaining fasteners. Torque to
specification.
Hydraulic Tank Retaining Fasteners, Dry 35 in-Ibs 4 Nm
Hydraulic Tank Drain Plug, Lubricated 26 in-Ibs 3 Nm
Install the hydraulic power pack into the component tray. Install the fitting and hydraulic hoses
onto the hydraulic power pack and torque.
Fill the tank with hydraulic oil to the middle of the dipstick. Do not overfill.
Activate the pump to fill the hydraulic system with oil and bleed the system of air.
COMPONENT DAMAGE HAZARD. THE PUMP CAN BE DAMAGED
IF OPERATED WITHOUT OIL. BE CAREFUL NOT TO EMPTY THE
HYDRAULIC TANK WHILE IN THE PROCESS OF FILLING THE
HYDRAULIC SYSTEM. DO NOT ALLOW THE PUMP TO CAVITATE.