Page 18 Micro19 - Operator’s Manual
August 2021Section 7 - Operating Instructions and Function Tests
control panel.
Test Drive and Braking
Press and hold the Function Enable Switch on the control handle.
Slowly move the control handle in the direction indicated by the blue up arrow on the control
panel until the machine begins to move, then return the handle to the center position.
Result: The machine should move in the direction that the blue up arrow points on the
control panel, then come to an abrupt stop.
Press and hold the Function Enable Switch on the control handle.
Slowly move the control handle in the direction indicated by the yellow down arrow on the control
panel until the machine begins to move, then return the handle to the center position.
Result: The machine should move in the direction that the yellow down arrow points on the
control panel, then come to an abrupt stop.
Note: The brakes must be able to hold the machine on any slope it is able to climb.
Test Limited Drive Speed
Press the lift Function Enable Switch. Raise the platform approximately 5 ft / 1.5 m from the
ground.
Press the drive function select switch.
Press and hold the Function Enable Switch on the control handle.
Slowly move the control handle to the full drive position.
Result: The maximum achievable drive speed with the platform raised should not exceed
0.55 ft per second / 16.7 cm/s.
If the drive speed with the platform raised exceeds 0.55 ft per second / 16.7 cm/s,
immediately tag and remove the machine from service.