Page 5 Micro19 - Operator’s Manual
August 2021
Electrocution Hazards
ELECTROCUTION HAZARD! THIS MACHINE IS NOT INSULATED!
DEATH OR SERIOUS INJURY will result from contact with or inadequate
clearance from any electrically charged conductor.
You must maintain a CLEARANCE OF AT LEAST 10 FEET (3.05 m)
between any part of the machine, or its load, and any electrical line or
apparatus carrying over 300 Volts up to 50,000 Volts. One foot (30.5 cm)
additional clearance is required for every additional 30,000 Volts.
Observe Minimum Safe Approach Distance.
Art_2824
Art_2823
This machine is not electrically insulated and will not provide protection from
contact with or proximity to electrical current.
Maintain safe distances from electrical power lines and apparatus in
accordance with applicable government regulations and the following chart:
Voltage Minimum Safe Approach Distance
Phase to Phase Feet Meters
0 to 300 Volts Avoid Contact
Over 300V to 50kv 10 3.1
Over 50KV to 200KV 15 4.6
Over 200KV to 350KV 20 6.1
Over 350KV to 500KV 25 7.6
Over 500KV to 750KV 35 10.7
Over 750KV to 1000KV 45 13.7
Allow for platform movement, electrical line sway or sag and beware of strong
or gusty winds.
Keep away from the machine if it contacts energized power lines. Personnel
on the ground or in the platform must not touch or operate the machine until
energized power lines are shut off.
Do not use the machine as a ground for welding.
Section 4 - Hazards
Electrocution Hazards