Do you have a question about the Medify Air MA-40 and is the answer not in the manual?
Instructions for opening and reattaching the back cover of the air purifier.
Guidance on proper placement and spacing for optimal air circulation.
General instructions for operating the air purifier after setup.
Details on turning the unit on/off and adjusting fan speed settings.
How to set the operating timer for the air purifier.
Explanation of the ionizer function and its indicator light.
Instructions for activating and deactivating the child lock feature.
Guidelines for cleaning the exterior of the air purifier with a cloth.
Instructions and indicator explanation for replacing the air filter.
Details of the lifetime warranty terms, conditions, and registration.
The Medify Air MA-40 is an air purifier designed to improve air quality through a multi-stage filtration system. It is suitable for use in homes and other indoor environments, aiming to remove various airborne particles and odors.
The core function of the MA-40 is air purification, achieved through a three-stage filtration process. The first stage is a pre-filter, which is responsible for capturing larger particles such as hair, fibers, and pet dander. This initial filtration helps to extend the life of the subsequent filters by preventing them from becoming clogged too quickly. The second stage utilizes a True HEPA H13 filter. This high-efficiency filter is tested to remove 99.9% of particles down to 0.1 microns, including pollen, dust mites, and other microscopic airborne particles that are invisible to the naked eye. The final stage is an activated carbon filter, which contains substantial carbon pellets. This filter is specifically designed to absorb and eliminate toxic odors, smoke, and formaldehyde from the air, contributing to a fresher indoor environment.
The MA-40 air purifier is designed for user-friendly operation and maintenance. Before initial use, it is crucial to remove all plastic packaging from the filters. The unit should be placed on a firm, leveled surface in a dry location, ensuring at least 10 inches of space between the back air intake and any walls or furniture to allow for proper air circulation. The air purifier is powered by plugging it into a standard AC outlet. Upon plugging in, the unit will beep, and all indicator lights will flash once before entering standby mode.
The control panel of the MA-40 features several buttons and indicators for easy management of its functions. The power button turns the unit on and off, with the unit starting in low speed when activated. There are four fan speed settings: low, medium, high, and sleep mode. Users can select their desired fan speed by pressing the speed button, with higher speeds resulting in faster air purification. The timer function allows users to set the operating duration for 1, 2, 4, or 8 hours, or to run continuously without a timer. An ionizer mode is also available, which can be turned on or off at the user's discretion, indicated by a lit indicator light when active. For safety and to prevent accidental changes to settings, a child-lock function is included. This mode disables all function keys except the child lock itself. To activate the child lock, the button must be held down for 3 to 5 seconds, and to deactivate it, the button needs to be held for 30 to 45 seconds.
Maintenance of the MA-40 primarily involves cleaning the unit and replacing the filters. The air purifier should be unplugged before any cleaning. The exterior of the unit can be wiped with a soft, wet cloth to remove accumulated dust. It is important not to use excessive water or any solvents, alcohol, or flammable cleaners, as these can damage the unit. The air intake and vents should also be kept free from dust. The filters themselves should not be vacuumed or washed, as this will clog them.
Filter replacement is a critical aspect of maintaining the MA-40's performance. The unit features a filter replacement indicator light that illuminates when the filters need to be changed. The Medify filter is a one-piece, three-stage filter designed for higher performance. To replace the filter, the back cover of the unit must first be removed. This is done by pressing the tabs on the back cover and pulling it slightly, then lifting it off. The old filter can then be removed by pulling on the small tab at the top. Before installing the new filter, all plastic packaging must be removed from it. The new filter should be placed into the air purifier with the white side facing outwards and the tab at the top facing the user. After the new filter is in place, the back cover is reinstalled by aligning the fixed slots and inserting the covers until they snap back into place. After installing a new filter and turning the unit back on, the filter indicator light needs to be reset. This is achieved by holding down both the FAN SPEED button and the IONIZER button simultaneously for 3-5 seconds. This action will turn off the indicator light and reset the filter timer for 3000 hours. It is crucial not to operate the air purifier without a filter installed.
The lifetime warranty for the MA-40 is contingent on several conditions, including timely replacement of filters. Filters should be replaced with genuine Medify Air replacement filters at least once every three to four months or after 2,500 hours of use, whichever comes first. This ensures optimal performance and adherence to warranty terms. The MA-40 is designed to be a reliable and effective solution for improving indoor air quality, with straightforward operation and maintenance procedures.
| Filter Type | HEPA H13 |
|---|---|
| Speeds | 3 |
| CADR Smoke | 330 |
| CADR Dust | 330 |
| CADR Pollen | 330 |
| Warranty | Lifetime |