Do you have a question about the Medify Air MA-40UV and is the answer not in the manual?
Removes hair, fibers, and large particles like dander.
Removes 99.99% of particles down to 0.1 microns, including PM2.5.
Removes toxic odors, smoke, and formaldehyde.
Produces negative ions to neutralize positively charged particles.
Freshens air by sterilization and disinfection function.
Place the machine in a dry location on a smooth and flat surface.
Press top buttons to release and lift the back cover.
Pull the old filter by the tab at the top.
Remove plastic packaging from the new filter before installing it.
Place new filter with white side facing you, tab at the top.
Securely replace the back cover after filter installation.
Unpack, place on a level surface, and plug in the air purifier.
Turn on/off unit and cycle through low, medium, high, and sleep fan speeds.
Set the operational timer for 1, 2, 4, or 8 hours.
Control the ionizer function, which freshens air when active.
Wipe the unit with a clean dry cloth; ensure vents are dust-free.
Indicator lights signal when the filter needs replacement.
Hold FAN SPEED and IONIZER buttons for 3-5 seconds to reset.
Details on maintaining the lifetime warranty, including registration and filter replacement.
The Medify Air MA-40UV is an air purifier designed to improve indoor air quality through a comprehensive five-step filtration system. Its primary function is to remove airborne pollutants, making the air safer and cleaner to breathe in various indoor environments such as homes, offices, and hotels.
The purification process begins with a Pre-Filter, which is the first line of defense against larger particles. This filter efficiently captures hair, fibers, and other substantial debris like pet dander, preventing them from clogging subsequent filters and extending their lifespan.
Following the pre-filter is the True HEPA H14 Filter. This is a high-grade HEPA filter, capable of removing an impressive 99.99% of particles as small as 0.1 microns. This includes common allergens and irritants such as smoke, pollen, dust mites, and other microscopic airborne contaminants. The H14 designation indicates a superior level of filtration compared to standard HEPA filters, offering enhanced protection against ultrafine particles.
Next in the system is the Activated Carbon Filter. This substantial filter is packed with carbon pellets specifically designed to absorb and neutralize toxic odors, smoke, and harmful volatile organic compounds (VOCs) like formaldehyde. It plays a crucial role in eliminating unpleasant smells and chemical pollutants from the air, contributing to a fresher indoor environment.
The fourth stage involves an Ionizer. This feature generates negative ions, which are released into the air to actively neutralize positively charged particles. These positively charged particles often include dust, pollen, and animal dander, as well as other airborne positive particles. By neutralizing them, the ionizer helps these particles clump together, making them easier for the filters to capture or causing them to settle out of the air. The ionizer function is optional and can be turned on or off by the user.
Finally, the MA-40UV incorporates UV Disinfection. This stage uses ultraviolet light to sterilize and disinfect the air, further enhancing its purity. The UV function helps to kill bacteria, viruses, and other microorganisms, providing an additional layer of protection against airborne pathogens. The UV function runs for 20 minutes automatically and then turns off, but can be manually turned off earlier if desired.
For optimal performance and longevity, the device requires proper installation and maintenance. Before initial use, it is crucial to remove all plastic packaging from the filters. The filters are a one-piece unit and should be installed with the white side facing outwards and the tab at the top facing the user. The back cover of the unit is easily removed by pressing tabs and pulling it off, allowing access for filter installation and replacement. When placing the air purifier, it is important to ensure at least 10 inches of space between the back air intake and any walls or furniture to allow for proper air circulation and prevent obstruction of the air intake or clean air outlet.
The control panel offers several user-friendly features. The Power Button turns the unit on and off, with the unit starting in low speed. The Fan Speed Settings include low, medium, high, and a sleep mode, allowing users to adjust the purification intensity based on their needs. A Timer Button provides options for 1, 2, 4, or 8 hours of operation, or no timer at all. The Ionizer Mode can be toggled on or off, indicated by a lit indicator light when active. The UV/Child-Lock Button activates the UV disinfection feature and also serves as a child lock. To engage the child lock, the button must be pressed and held for 3 to 5 seconds, disabling all other function keys except the child lock itself. To disengage, it must be held for 30 to 45 seconds.
Maintenance primarily involves cleaning and filter replacement. The unit should be unplugged before any cleaning. A soft, wet cloth should be used to clean the exterior, avoiding excessive water or harsh solvents like Benzene, Alcohol, or other flammable cleaners. It is important to keep the air intake and vents free from dust. The filters themselves should never be vacuumed or washed, as this can clog them.
The air purifier features a Filter Replacement Indicator Light that illuminates when the filters need to be replaced, typically after 3,000 hours of use or every four to five months, whichever comes first. To replace the filters, the unit must be unplugged. The old filter is removed by pulling on a small tab at the top. After installing the new filter and replacing the back cover, the filter indicator light needs to be reset. This is done by pressing and holding both the FAN SPEED button and the IONIZER button simultaneously for 3-5 seconds. This action will turn off the indicator light and reset the timer for another 3,000 hours of filter life.
The Medify Air MA-40UV is designed for ease of use and effective air purification, providing a higher standard of air quality through its multi-stage filtration and disinfection system. Its lifetime warranty, contingent on timely filter replacement with genuine Medify Air filters, underscores the manufacturer's commitment to long-term performance and customer satisfaction.
| Room Coverage | 1, 600 sq. ft. |
|---|---|
| Filter Type | HEPA H13 |
| UV-C Light | Yes |
| Fan Speeds | 3 |
| Power Consumption | 100 W |
| Number of Filters | 3 |