6.3. Error information
The following table contains some typical errors along with the error details and remedies.
AH257_ Bandsaws Trouble shooting guide
Code
Error name 異常名稱
Remedy
排除方法
00
正常停機
Machine stops normally
1.Press Blade-ascending button 按鋸帶上升按鈕
01
上升電磁閥異常
Solenoid - ascending frame abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
02
下限開關異常
Lower limit switch – descending frame
abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
03
前後限卡死異常
Front/rear limit switch – bar feeding
saddle abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
04
前進電磁閥異常
Solenoid – feeding forward abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
05
無料異常
No material switch abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
06
快速下降碰到下限開關異常
Saw frame touches fast to lower limit
switch abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
07
鋸帶近接開關異常
Sensor – switch abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
10
上限開關異常
Upper limit switch abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
11
前極限開關異常
Front limit switch abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
12
後退電磁閥異常
Feed-backward solenoid abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
13
後極限開關異常
Rear limit switch abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
14
變頻器出現異常
Inverter abnormal
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
15
變頻器故障
Inverter-breakdown
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕
16
17
油壓馬達過負載 OR 水泵馬達過負載
Hyd. Motor overload or coolant pump
overload
1.Eliminate breakdown
2.Press Blade-ascending button
1.排除故障原因
2.按鋸帶上升按鈕