EasyManua.ls Logo

Megger BMM2500 - Technical Specifications

Megger BMM2500
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specification
22
(All quoted accuracies are at +20ºC.)
INSULATION RANGES
Nominal Test 250V,500V,1000V (BMM2500)
Voltage (d.c.): 50V,100V,250V,500V,1000V (BMM2580)
Test voltage accuracy: +15% maximum on open circuit
Short circuit current: < 2 mA
Test Current on load: 1mA at min. pass value of insulation
specified in BS7671, HD384 and
IEC 364, 2mA max.
Accuracy:
(BMM2500)
Range Full Scale Accuracy
1000V 20GΩ ± 2% ± 2 digits ± 0,2% per GΩ
500V 10GΩ ± 2% ± 2 digits ± 0,4% per GΩ
250V 5GΩ ± 2% ± 2 digits ± 0,8% per GΩ
(BMM2580)
Range Full Scale Accuracy
1000V 200GΩ ± 2% ± 2 digits ± 0,2% per GΩ
500V 100GΩ ± 2% ± 2 digits ± 0,4% per GΩ
250V 50GΩ ± 2% ± 2 digits ± 0,8% per GΩ
100V 20GΩ ± 2% ± 2 digits ± 2,0% per GΩ
50V 10GΩ ± 2% ± 2 digits ± 4,0% per GΩ
Note: Above specifications only apply when high quality
silicone leads are being used.
Measuring Range:
0,01MΩ to 200GΩ (0-100GΩ on analogue scale).
EN61557 Operating range: 0,10MΩ to 1,00GΩ
Leakage Current: 10% ±3digits
CONTINUITY
Measuring Range: 0,01Ω to 99,9Ω (0 to 10Ω on
analogue scale)
EN61557 Operating range: 0,10Ω to 99,9Ω
Accuracy: ±2% ±2 digits
Open circuit voltage: 5V ±1V
Test current: 210mA ±10mA (0-2Ω)
Zero offset at probes: 0,10Ω typical
Lead resistance zeroing: Up to 9,99Ω
Noise rejection: 1V rms 50/60Hz
Buzzer: Operates at less than 5Ω
(approx).
RESISTANCE
Measuring Range: 0,01kΩ to 9,99MΩ (0 to
100MΩ on analogue scale)
Accuracy: ±3% ±2 digits
Open circuit voltage: 5V ±1V
Short circuit current: 25µA ±5 µA