EasyManua.ls Logo

Megger BMM2500 User Manual

Megger BMM2500
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
This instrument is manufactured in the United Kingdom.
The company reserves the right to change the specification or design without prior notice.
Megger is a registered trademark
Part No. 6172-491 V06 0207
www.megger.com
Megger Limited
Archcliffe Road, Dover
Kent CT17 9EN England
T +44 (0)1 304 502101
F +44 (0)1 304 207342
E uksales@megger.com
Megger
4271 Bronze Way, Dallas,
Texas 75237-1019 USA
T +1 800 723 2861 (USA
ONLY)
T +1 214 333 3201
F +1 214 331 7399
E ussales@megger.com
Megger
Z.A. Du Buisson de la
Couldre
23 rue Eugène Henaff
78190 TRAPPES France
T +33 (0)1 30.16.08.90
F +33 (0)1 34.61.23.77
E infos@megger.com
Megger Pty Limited
Unit 26 9 Hudson Avenue
Castle Hill
Sydney NSW 2125
Australia
T +61 (0)2 9659 2005
F +61 (0)2 9659 2201
E ausales@megger.com
Megger Limited
110 Milner Avenue Unit 1
Scarborough Ontario
M1S 3R2
Canada
T +1 416 298 9688 (Canada
only)
T +1 416 298 6770
F +1 416 298 0848
E casales@megger.com
M
Question and Answer IconNeed help?

Do you have a question about the Megger BMM2500 and is the answer not in the manual?

Megger BMM2500 Specifications

General IconGeneral
TypeDigital Multimeter
DC Voltage Ranges200mV, 2V, 20V, 200V, 1000V
AC Voltage Ranges200mV, 2V, 20V, 200V, 750V
Continuity TestYes
Diode TestYes
Safety RatingCAT III 1000V, CAT IV 600V
Power Supply9V Battery
Temperature Range-20°C to 1000°C
DC Current Ranges200μA, 2mA, 20mA, 200mA, 10A
AC Current Ranges200μA, 2mA, 20mA, 200mA, 10A
DisplayLCD
Capacitance Range20nF, 200nF, 2µF, 20µF
Battery Type9V
Resistance Ranges200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ
Frequency Range10Hz to 1MHz

Summary

Instrument Symbols and Safety

Instrument Symbols

Visual indicators and their meanings used on the instrument.

Safety Warnings

Essential safety precautions and guidelines for instrument use.

General Description and Operation

General Description

Overview of the BMM2500 Series insulation multimeters and their capabilities.

Instrument Operation

Details on operating the instrument, including warnings and test types.

Measurement Functions

Insulation Tests

Procedure and details for performing insulation resistance tests.

Continuity Testing

How to perform continuity tests and zero lead resistance.

Resistance and Diode Testing

Details on resistance measurements, error sources, and diode testing.

Voltage and Millivolt Measurements

Performing AC/DC voltage and millivolt measurements, including zeroing.

Capacitance and Milliamps Tests

Testing capacitance and measuring current, with zeroing procedures.

Data Management and Datalogging

Data Storage and Management

Managing test results, including distribution boards and saving.

Datalogging Operations

Details on data logging, session management, and comparisons.

Setup, Maintenance, and Specifications

Setup Modes and Configuration

Configuring printer settings, language, and data-logging functions.

Maintenance

Battery replacement, fuse checks, and accessory usage.

Technical Specifications

Key performance metrics, ranges, accuracies, and error details.

Compliance, Accessories, and Support

Compliance and Environmental Details

Safety standards, power supply, and operating environmental conditions.

Accessories and Publications

List of supplied and optional accessories, along with relevant publications.

Repair and Warranty Information

Details on instrument warranty, approved repairers, and return procedures.

Related product manuals