Periodic maintenance can improve the performance and extend the working life of a bill accep-
tor. Additional attention may be required if the bill acceptor becomes inoperable due to a
jammed object or acceptance rates fall below normal.
Cleaning And Clearing The Bill Path and Sensor Area.
Note: You must remove the Acceptor Module from the chassis to open the front sensor area. Forcing the bill path open
without removing the Acceptor Module from the chassis will damage the connector board located at the rear of the
Acceptor Module.
• Release the Acceptor Module from its normal operating position.
• Open the Acceptor Module unit by pressing up on the yellow cap.
• Clear the bill path area of any foreign objects.
• Clean bill path and sensor areas as needed.
For stubborn dirt, a small amount of mild non-abrasive soap may be applied to a damp cloth.
Make sure no streaks or residual from the cleaning product remain on the bill path.
Note: Never use a petroleum-based product to clean this device! Petroleum based products will damage the bill
path.
Calibration
The SC66 series bill acceptor does not require any calibration in the field. Thus, the unit has no
switch settings or calibration mode that allows a user to perform a calibration. If, for any reason,
the unit requires calibration, it may only be done by one of our trained technicians.
MAINTENANCE