Care and maintenance
59
GB
41
42
40
43
43
Fig. 24: Removing the milk unit, 2
1. Pull the milk hose o the appliance.
2. Push the outlet (7) down as far as it will
go.
3. Press the locking mechanism (43) of
the milk unit(40) together using two
ngers and pull the milk unit down-
wards o the outlet.
4. Pull the milk distributor (41) upwards
out of the milk unit.
5. Pull the inlet (42) out upwards.
6. Clean the individual parts with warm
water. Use the enclosed cleaning brush,
a soft, damp cloth and normal wash-
ing-up liquid.
Installation is carried out as described in
reverse order.
Information
To install, push the milk unit(40) onto the
outlet (7) using both hands. Make sure
that the locking mechanism(43) audibly
engages on both sides.
9.6 "Cleaning coee system"
programme
This cleaning programme is used to
remove residues and coee oil residues
with the aid of coee machine cleaning
agents.
To avoid damage to the appliance, we
recommend carrying out the cleaning pro-
gramme every 2 months or as requested
by the appliance.
Before starting the cleaning programme,
clean the brewing unit and the interior
(see section9.3, page57).
The cleaning programme takes approx-
imately 15 minutes and should not be
interrupted.
CAUTION
Contact with coee machine cleaning
agent may lead to eye and skin irritation.
Observe the processing instructions on
the packaging of the coee machine
cleaning agent.
ATTENTION
The use of unsuitable coee machine
cleaning agents can damage the appli-
ance.
Only use Melitta® PERFECT CLEAN
cleaning tabs for fully automatic coee
makers.
Requirement: The appliance is ready for
operation.
1. Press the "menu/ok" button for 2sec-
onds.
» The menu appears on the display.
2. Navigate to the Care > Cleaning coee
system menu.
3. Use the arrow buttons to select Start
and conrm with "menu/ok".
4. Follow the further instructions on the
display up to the end of the cleaning
programme.
» The appliance is ready for operation.
9.7 "Descaling" programme
The descaling programme is used to
remove limescale deposits in the interior
of the appliance with coee machine
descaling agents.
To avoid damage to the appliance, we rec-
ommend carrying out the descaling pro-
gramme every 3 months or as requested
by the appliance.